Navigation

Conventional Ultrasonics | | |

Ultrasonic Systems & Scanners | | |

Phased Array/TOFD | | |

Fire Sprinkler Inspection Systems | | |

Resonant Acoustic Method | | |

Eddy Current | | |

X-Ray | | |

Magnetic Particle | | |

Liquid Penetrant | | |

Visual Optical | | |

Mechanical, Optical and other Testing Accessories | | |

Newsonic Mach I

Adobe File

Specifications

Test Range 0.500 in to 200 in (10 mm to 5000 mm)(in steel). In Hot Key Mode it has 13 preset values. In Fine Mode it is adjustable in step of 1mm.
Velocity 0.0400 in/µs to 0.4000 in/µs (1000 m/sec to 9999 m/sec). In Hot Key Mode it has 7 preset values. In Fine Mode it is adjustable in step of 1 meter/second,
Delay Variable from 0 to 100 in (0 to 3000 mm)
Gain  Total Amplifier Gain: 140 dB. Calibrated Gain: 100 dB adjustable in steps of 0.5,1,2,6,12 or 20 dB.
Rejection 0 to 80% FSH with LED indication
Rectification Full wave rectification with filtering.
Frequency Broad Band amplifier 0.5 MHz to 15 MHz.
Test Modes Pulse Echo and Transmit/Receiver.
Connectors  BNC and LEMO (Size 1) both are provided.
Monitor Dual gate adjustable in 1% of Screen width with Positive/Negative logic, Gate Expand modes.
Gate Expand Expands Range to width of the gate.
A-Scan Memory* 200 Trace Patterns can be stored, recalled, printed or transferred to PC via RS-232 serial port.
Calibration Setup 50 different calibration set-ups can be Stored and Recalled.
Software* Using “NewSoft TFT” software A-Scan with calibration set-ups can be transferred to PC via RS-232 serial link for storage in PC or printing.
Printer Attachment  IBM compatible Printer having serial port can be directly attached to main unit for printing of stored A-Scan waveform with calibration data.
Display High brightness Color TFT LCD Display. Display area 320 x 240 pixel (122x92 mm). Eleven different color scheme options.
Full Screen  By pressing Zoom key A-Scan can be displayed in Full Screen area.
Reference A-Scan*  Reference A-Scan pattern of standard test object can be saved and recalled in the background for easy comparison during testing.
DAC*  DAC curve can be entered using minimum 2 to maximum 10 points and then digitally drawn with –6dB and –14dB curves.
Digital Readout* and Trig. Function Thickness/Depth can be displayed in digital readout when using a normal probe and Beam path, Surface Distance and Depth are directly displayed when angle probe is in use.
Update Rate 50Hz
Power Lithium-Ion Battery pack 14.4VDC, 4AH, gives 8 hours continuous operation from fully charged battery.
Charger Input Voltage 100 to 240 VAC. Charges status indicator is provided.
Temperature 32° to 131°F (0 to 55° C)
Size 5.98 in H x 10.04 in W x 2.76 in D (152x255x70 mm)
Weight 5.07 lbs (2.3 kg.) with Battery.

 

If you don’t see what you need, please give us a call at 713-861-3270 or email us at customerservice@stroudsystems.com and we’ll be glad to answer any questions you may have. Thanks for visiting with us!